CREATE YOUR LISTING

Epower Electronics Science Company

Main products:

Home/Products/Portable Syringe Pump Drug Library 3 Work Mode , Large Syringe Pump/

Portable Syringe Pump Drug Library 3 Work Mode , Large Syringe Pump

Update time:2022-02-08 14:33:47
Price:Negotiable
Min Order:1 Set / Sets
  • 7 days
  • T/T L/C D/P D/A
  • 0 Set / Sets per Month

Basic Info

Brand NameEpowerModel NumberXB-1500Place of OriginChina

Product Description


Product Description




Delivery Time:5-7 working days after received payment
Certification:CE/ISO

Portable Syringe Pump Drug Library & 3 Work Mode , Large Syringe Pump​


Product advantages


Injection modes: Rate Mode, Time Mode and Body Weight Mode.
Applicable for all standard 5, 10, 20, 30, and 50(60) syringes .
Bolus function.
Multi- language , English, Spanish, Russian etc.
Drug library and factory default function.
4.3 inches colorful LCD screen.
Button Operation history records.
Time and calendar display.

Technical parameters

























































Applicable syringes



All brands of standard syringes: 5, 10, 20, 30 and 50 (60) ml



Bolus rate



5ml: 100ml/h         10ml: 200ml/h      20ml: 400ml/h


30ml: 400-600ml/h    50ml:400-1500ml/h



Injection increment



0.1ml/h



Injection rate range



5ml: 0.1ml/h---100ml/h         10ml: 0.1ml/h---200ml/h


20ml: 0.1ml/h---400ml/h        30ml: 0.1ml/h---600ml/h


50(60)ml: 0.1ml/h---1500ml/h



Injection accuracy



±2%



Drug names



More than 20 drug names, such as Penicillin, Vancomycin, Pitocin, Insulin, Lidocaine, Heparin, Atropin, Dopamine, Epinephrine, and so on.



KVO rate



Adjustable, 0.1ml/h-5.0ml/h, choose “OFF”to cancel



Selectable modes



Rate mode, Time mode, Body weight mode



Rate mode



0.1~1500ml/h(max value depends on the syringe size)



Body weight mode



Body weight: 0.1~300kg    Drug limit: 0.1~999.9mg


Volume limit: 0.1~999.9ml   Dose:0.1~9999.9mg


(Subject to unit, dosage, liquid, weight and syringe)


Unit: mg/kg/h, ug/kg/min



Time mode



Volume limit: 0.1-999.9ml    Time: 1-2000min



Accumulated volume



0.1~9999.9ml



Preset range



0.1~9999.9ml



Alarm function



NEAR, OVER, OCCL., syringe disengaged, no AC power supply, low battery, serious low battery, error 1/2/3, preset volume alarm



Occlusion value



0.04Mpa – 0.16Mpa



Battery



Rechargeable lithium polymer battery 7.4V, 3000mA, working for 4 hours(25ml/h) after being fully charged



Preset time



0-99hour, 59 minutes



Panel instructions



Infusion rate ②Accumulated injection volume ③Syringe pump ④Battery capacity ⑤Battery charging indication ⑥AC power indicator  ⑦BED NO.  ⑧Alarm information, etc

Power supply



AC100~240V   50/60HZ



Max power consumption



25VA



Classification



Class II, type BF



EMC



Meet the requirements of IEC60601-1-2(2007 version)



Electrical safety



Meet the requirements of EN60601-1:1990+A1:1993+A2:1995



Operation condition



Environment temperature: 5℃~+40℃, air pressure (86~106) kPa,  relative humidity≦80%



Storage condition



Environment temperature: -20℃~+55℃, air pressure (50~106)kPa,  relative humidity≦95%



Gross weight



<2.8kg



Overall maximum size



300*139*100mm (L*W*H)



Medical Syringe Pump



Recommended Products

Recently Viewed

Contact Us

  • Epower Electronics Science Company