CREATE YOUR LISTING

Ada Power Electronics Co.,Limited

Main products: Low Voltage Variable Frequency Drive ,Solar Variable Frequency Drive ,3 Phase Variable Frequency Drive

Home/Products/single / 3 Phase 220V Online Uninterruptible Power Supply UPS with LCD + LED Display/

single / 3 Phase 220V Online Uninterruptible Power Supply UPS with LCD + LED Display

Update time:2022-02-26 09:51:43
Price:Negotiable
Min Order:1 Set / Sets
  • 7 days
  • T/T L/C D/P D/A
  • 0 Set / Sets per Month

Basic Info

Model NumberTD31 30-40KPlace of OriginChina

Product Description


Product Description




Delivery Time:2 weeks
Certification:ISO 9001,CE


220V Low Frequency Online UPS  LCD+LED Display High Loading Capacity



Quick Detail:


Rate Capacity:6KVA,10KVA,15KVA,20KVA,30KVA,40KVA
Power factor:0.8
Input:380Vac±25% (3 Phase)
Output:220Vac Line Voltage (1 Phase)
System Noise Level(1M):≤55dB
System Isolate Impedance(Ω):>2M(500VDC)


Specifications:




























































































MODEL (3 Phase Input/1 Phase Output)

TD31 6K

TD31 10K

TD31 15K

TD31 20K

TD31 30K

TD31 40K

Input Mains

Rated Voltage(V)

380V(Line Voltage)

Rated Voltage & Range(V)

380V±25%

Frequency & Range(Hz)

46Hz-54Hz

Bypass Input

Rated Voltage(V)

220V(Line Voltage)

Rated Voltage & Range(V)

380V±25%

Frequency & Range(Hz)

46Hz-54Hz

Output

Rated Power


6KVA/4.8KW



10KVA/8KW


15KVA/12KW



20KVA/16KW


30KVA/24KW




40KVA/32KW



Rated Voltage(V)

220V(Line Voltage)

Rated Voltage & Stability

220V±2%

THDV

≤3%

≤10%

Output Power factor

0.8(Lag)

Tracking Fruquency & Range(Hz)

46Hz~64Hz

Fruquency & Stability(Battery Inverter)

(50+0.1)Hz/60+0.1)Hz

Overload Capability

Less than 105%±5% for overload alarm;

105%±5%~125%±5% for 2 minutes;

125%±5%~150%±5% for 30 second;

More than 150%±5% for 0.5 second;

Converting time(Normal Mode)

<1mS

Converting time(ECO Mode)

<25mS

System

System Efficiency(Linear Load)

≥82%

≥87%

≥82%

≥88%

Display

LCD+LED


EMS/EMI



Transmission


IEC EN62040-02



Radiation


Resisting Interference




IEC 61000-4-2.4.5 Level IV, IEC61000-4-3 Level III



Safety Requirements


GB4943-2001/IEC62040-1



Noise Level(1M)

≤55dB

Isolate Impedance(Ω)

>2M(500VDC)

Surge Current Protection

IEC60664-1 IV

Environment

Operating Temperature


0℃ - 40℃



Elevation

<1000m

Storing Temperature

-15℃ - 45℃

Operation Humidity

20% - 95%

Battery

192VDC


384VDC



UPS Size(W x H x D)mm


260x717x560



370x900x655


455x1055x830




455x1045x830




515x1135x830



Package Size(WxHxD)mm




Recommended Products

Recently Viewed

Contact Us

  • Ada Power Electronics Co.,Limited