CREATE YOUR LISTING

Ada Power Electronics Co.,Limited

Main products: Low Voltage Variable Frequency Drive ,Solar Variable Frequency Drive ,3 Phase Variable Frequency Drive

Home/Products/Single Phase High Frequency Online UPS 240V 36VDC/

Single Phase High Frequency Online UPS 240V 36VDC

Update time:2022-02-26 09:52:34
Price:Negotiable
Min Order:1 Piece / Pieces
  • 7 days
  • T/T L/C D/P D/A
  • 0 Piece / Pieces per Month

Basic Info

Brand NameSunshineModel NumberVT1K(1KS/2KS/2KS/3KS/3KS)Place of OriginChina

Product Description


Product Description




Delivery Time:2 weeks
Certification:ISO 9001,CE


Single Phase High Frequency Online UPS 240V 36VDC



Quick Detail:


Rate Capacity:1K-3KVA
Power factor:0.8
Input:(90±5)VAC~ (300±5)VAC
Output:220Vac
Input system:Single phase & earth ground
Voltage precision:±2%


Specifications:



































































MODEL

VT1K

VT1KS

VT2K

VT2KS

VT3K

VT3KS


Rating



1KVA/800W

2KVA/1600W

3KVA/2400W

Input


Input system




Single phase & earth ground




Voltage range




(90±5)VAC~ (300±5)VAC




Power factor




≥0.99




Voltage range of bypass




(80±5)VAC~ (286±5)VAC (default: 80VAC~264VAC 



Could be adjusted by software)




Output




Output system




Single phase & earth ground




Rated voltage




220VAC  ①




Power factor




0.8




Voltage precision




±2%



Output  frequency


Normal mode




1.The output frequency synchronizes with the input frequency 



when the input frequency is in the range of  46 Hz~ 54 Hz



2.The output frequency is 50Hz when the inpu



t frequency is not in the range of 46 Hz~ 54 Hz



3.Can be set as 60Hz




Battery mode




Inverter overload 



capacity (Utility power, 25℃)




105%±5%<Load≤125%±5% 50s transfer to bypass



125%±5%< Load <150%±5% 25s transfer to bypass



Load > 150%±5%, 300ms transfer to bypass




Transfer time




0ms (Normal mode←→ Battery mode)




<4ms (Normal mode←→Bypass mode)




Crest factor




3:1




Battery




Batteries voltage




36VDC



72VDC/96VDC

96VDC/72VDC


Battery quantity




3




None




6/8




None




8/6




None




Battery Type




Sealed maintenance-free lead –acid battery of battery voltage 12V/7AH




Backup Time (25℃)




Full load≥5min (Standard)




Charge current




1A




6.5A




1A




5.5A




1A




5.5A



① Note1: Output voltage can be set: 200V/208V/220V/230V/240V.


Active input power factor correction (PFC): Digitalized control of the PFC enable the UPS to keep input power factor above 0.99 to prevent possible electric grid pollution and meanwhile mostly save the cost.



Wide range of input voltage and



Recommended Products