Introduction: AccuSine / 3L, active power filter
Applications - applicable to industrial capacity load
Adopts rectifier
Adopts inverter
Responding to large UPS
Adopts frequency electric furnace
Adopts electric arc furnace
Responding to... ..
Product characteristics - advanced harmonic detection principle
Responding to AccuSine / 3L real-time tracking harmonic detection
Responding to response speed
Responding filter range
Product characteristics - reaction speed, short response time
Responding to 100us response time
Responding to step change all the time harmonic responses 10ms less
Product characteristics - filter efficiency
While responding filter 2 ~ 5 times harmonic
Responding to filter out the filter can be selected
Can be selected number of responding to 0-100% output quotas
Adopts the high frequency IGBT 20KHz switch
Under the second-ranking rated power THDI < 5%
Responding to inject current single-phase, unbalanced system
Responding to satisfy the GB/T14549-93 and IEEE519 two standards
Product characteristics - powerful expansion ability
Adopts parallel, the biggest 10 sets up 3000A harmonic current compensation
Responding to share a set of transformer
Product characteristics - 225% filter can compensate reactive current capacity
Responding to eliminate flicker
Welding machine adopts load
Adopts electric arc furnace
Responding to...
Product characteristics - product operation independence
Every machine adopts independence of active power filter controller
Adopts parallel operation between multiple filters will influence each other
Product characteristics - convenient intuitive interface
Display:
Touch screen 3.8 inches
Load parameters and operation status display
Alarm and fault status display
Operation:
Start and stop touch-key
Graphics instructions
Functions:
Operation, stop the operation mode
Parameters monitor operation mode
The mode of system parameters
Communication: MODBUS
MODBUSSchneider Electric 2010/03/23-27 - EM
Other products
Can only responding filter, also can filter and reactive power compensation
Responding to provide users node, convenient operation monitoring equipment customers
With the system adopts not in resonance
Convenient installation, responding to open transformer
Responding to plus cabinet put oneself in another's position
Suitable for various types of responding to load
Adopts independence, guarantee system protection
Adopts automatic limit 100% output capacity, won't happen rated danger of overload