Main products: Control Modules & Infrastructure , High-Response Servo Valves,Positioners & Limit Switches,Positioner, control cable,pneumatic actuator,Weishaupt burner,Flame detection,Carlo Gavazzi Dupline Fieldbus,Burkert solenoid valve,N-TRON Switch,Fireye Flame detector,GLUKE encoder,SICK Photoelectric Sensor

Home/Products/Carlo Gavazzi Dupline/Carlo Gavazzi Dupline Fieldbus Tail Unit DT01/
Carlo Gavazzi   Dupline Fieldbus   Tail Unit   DT01
Carlo Gavazzi   Dupline Fieldbus   Tail Unit   DT01 - Image 1

Carlo Gavazzi Dupline Fieldbus Tail Unit DT01

Update time:2026-08-07 09:49:45
Price:¥ 550 - ¥ 550 / unit
Min Order:1 unit

Product Description


Carlo Gavazzi DT01 – Dupline Cable Termination Unit

The Carlo Gavazzi DT01 is a specialized passive termination device designed exclusively for the Dupline® two-wire fieldbus system. As a line terminator (commonly referred to as a "tail unit"), the DT01 ensures signal integrity and reliable data transmission across extended network distances by eliminating signal distortion caused by reflections at cable ends. In any fieldbus network, when signals travel to the end of an improperly terminated cable, reflections occur and interfere with the original signal, causing waveform distortion, data loss, node dropouts, or module malfunctions. The DT01 solves this critical issue through built-in termination resistance and filtering circuitry, making it an indispensable component for any Dupline network.

Key Features

Passive Termination – The DT01 is a passive device requiring no external power supply, drawing only a typical current of 220 µA with power dissipation not exceeding 10 mW. This low-power design ensures minimal impact on system performance while delivering essential termination functionality.

Reflection Elimination – By providing proper impedance matching at the bus endpoint, the DT01 absorbs excess signal energy and prevents reflections that would otherwise degrade data transmission quality. This ensures waveform integrity and reliable communication across the entire network.

Superior Noise Immunity – The module is equipped with high-quality filtering capacitors that suppress electromagnetic and radio-frequency interference (EMI/RFI) from motors, variable frequency drives, and high-power equipment. The design complies with EN 61000-6-2 industrial immunity standards.

Compact H1-Housing Design – The DT01 features a space-saving H1-housing that supports 35mm DIN rail mounting according to EN 50022 standards, enabling quick and easy integration into industrial control panels.

IP20 Protection Rating – Rated IP20 with pollution degree 3 per IEC 60664, the module is suitable for installation in control cabinets and industrial environments.

Wide Operating Temperature Range – The DT01 operates reliably from -20°C to +50°C (-4°F to +122°F), with storage capability from -50°C to +85°C (-58°F to 185°F).

Universal Compatibility – Fully compatible with all Dupline series modules, including digital input/output modules (G501 series), analog modules (GAP series), hand-held programmers, gateways, and repeaters.

RoHS Compliant – The DT01 meets RoHS compliance standards for environmentally responsible manufacturing.

Technical Specifications


ParameterSpecification
ModelDT01
Product TypeDupline Cable Termination Unit / Line Terminator
Bus SystemDupline® Fieldbus
Termination Impedance120Ω (±5%)
Operating Voltage8.2 – 10.8 V AC/DC
Current ConsumptionTyp. 220 µA (passive, no external power)
Power Dissipation≤ 10 mW
Mounting35mm DIN rail (EN 50022)
HousingH1-housing
Protection RatingIP20
Pollution Degree3 (per IEC 60664)
Operating Temperature-20°C to +50°C
Storage Temperature-50°C to +85°C
Relative Humidity0 – 80% (non-condensing)
Mechanical Shock15G (11ms)
Mechanical Vibration2G (6 – 55 Hz)
WeightApprox. 45 g
OriginItaly (COO: IT)
RoHS ComplianceYes
Product StatusActive

Installation Guidelines

Proper installation of the DT01 is essential for ensuring bus signal stability and reliable data transmission:

Placement – The DT01 must be installed at the end point of each Dupline bus segment. It should be placed at the farthest physical node of the network to provide proper electrical termination.

When Termination Is Required – The DT01 becomes necessary when the distance between the channel generator and the cable end exceeds 1.2 kilometers. For installations exceeding 2 kilometers, proper termination becomes critical to prevent signal degradation.

Branched Configurations – In branched cable configurations, additional DT01 units should only be installed when the distance between termination points exceeds 1.2 kilometers, as unnecessary units increase cable capacitance and reduce maximum transmission distance.

Wiring – Connect the DT01 according to the Dupline network diagram, ensuring correct polarity. Use shielded twisted-pair cables to further enhance signal immunity. Avoid routing bus cables parallel to high-power load cables.

Mounting – Secure the DT01 on a 35mm DIN rail within the control cabinet. Ensure the module is firmly seated and not exposed to excessive heat sources.

Verification – After installation, use a Dupline network tester (such as the GTU8) to verify signal quality and confirm termination integrity. Observe the status indicator LED for proper operation.

Applications

The Carlo Gavazzi DT01 line terminator serves a vital role across a wide spectrum of industrial and building automation applications:

  • Industrial Automation Systems – Production lines, packaging machinery, and conveyor systems where reliable sensor and actuator communication is critical
  • Building Automation – Lighting control networks, security systems, HVAC monitoring, and energy management systems
  • Process Control – Chemical processing, food and beverage production, and energy management facilities requiring stable data acquisition and real-time control
  • Power & Energy Monitoring – Remote monitoring and centralized data acquisition in power, gas, and water utility systems
  • Smart Factory & IIoT – Distributed control systems supporting large-scale industrial data transmission
  • Warehouse & Logistics – Large-scale facility automation with extended cable runs for comprehensive sensor and actuator networks
  • Infrastructure Monitoring – Tunnel ventilation, railway signaling, and other infrastructure applications requiring long-distance fieldbus communication

System Integration

The DT01 integrates seamlessly into the complete Dupline fieldbus ecosystem, working in conjunction with:

  • Dupline Channel Generators (such as GS3390) – For bus signal generation
  • Dupline I/O Modules – Digital and analog input/output modules (G501 series, etc.)
  • Dupline Gateways (such as SD2DUG24) – For integration with higher-level fieldbus systems and PLCs
  • Dupline Repeaters (such as SB2REP230) – For extending bus transmission distances
  • GAP1605 Hand-Held Programmer – For system configuration and addressing

The Dupline system supports bus, star, and tree topologies without requiring complex termination resistors at every node. The DT01 provides the necessary endpoint termination to maintain correct electrical impedance across the entire system.

Why Choose the DT01?

  • Guarantee Signal Integrity – Prevents data loss and communication errors caused by signal reflections at cable ends
  • Zero Maintenance – Passive design with no external power required means no ongoing maintenance costs
  • Simplify Installation – Compact DIN-rail mount design enables quick deployment in any industrial control panel
  • Enhance System Reliability – Superior noise immunity ensures stable communication even in harsh industrial environments with high EMI
  • Universal Compatibility – Works with all Dupline series modules for seamless system integration
  • Proven Technology – Backed by Carlo Gavazzi's decades of expertise in industrial automation and fieldbus technology
  • Cost-Effective – Reduces network failures and downtime while extending the reliable operating life of the entire fieldbus system

The Carlo Gavazzi DT01 Dupline Cable Termination Unit is a small yet critical component that ensures the smooth operation of the entire Dupline fieldbus system. By providing proper signal termination, impedance matching, and noise suppression, the DT01 safeguards data transmission integrity across extended network distances – making it an essential investment for any engineer seeking to build a robust, reliable, and high-performance Dupline-based distributed control system.