CREATE YOUR LISTING

Guangdong Derui Testing Equipment Co., Ltd.

Main products: Climatic Chamber ,Thermal Shock Test,Weathering Aging Test Series,Walk-in Test Chamber,IP (Rain and Dust) Test Series,Battery Test Series,Vibration System

Home/Products/Temperature Humidity Test Chamber Temperature Cycling Testing/Automatic Industrial Drying Oven with Overheat Protection for Electronics/

Automatic Industrial Drying Oven with Overheat Protection for Electronics

Update time:2025-03-27 03:29:17
Price:$ 2600 - $ 2600 / unit
Min Order:1 unit

Product Description

Equipment modelDR - H205
Drying oven work sizeDeep 960 ( L ) x width1760 ( W ) x 1420 mm ( H )
Drying oven outside diameter sizeDeep 1200 ( L ) x width 2200 ( W ) x 1860 mm ( H )
The rated powerThree phase four wire , 380 v , 50 hz
The highest working temperature300°C
Using the temperatureRoom temperature + 10 ~ 300 °C can be arbitrarily set
Heating zones1 zone
Heating element connectionY
Heating power24 kw
The temperature control modeUsing digital intelligent microcomputer PLD temperature control system .
Temperature control precision±1°C
Outer furnace wall temperatureTemperature 35 °C or less
Drying oven door wayManually turn
Hot air circulation fan370 w x 1

Y非标工业烘箱实拍7.jpg

The overheating protection mechanism works as follows in an automatic industrial drying oven:

1. Temperature monitoring

Temperature sensors, such as thermistors, thermocouples, etc., are installed inside the drying oven, and these sensors are able to monitor the temperature changes inside the oven in real time. They are usually distributed in different locations of the drying box to ensure that the temperature of each area can be accurately detected.

2. Temperature Comparison

The sensor transmits the detected temperature signal to the control system. A temperature threshold is pre-set in the control system. When the actual temperature exceeds this threshold, the system will immediately activate the protection mechanism. This threshold is usually set according to the temperature tolerance of the electronic components and the requirements of the drying process.

3. Protection Execution

Once the temperature exceeds the set threshold, the control system will quickly take measures to protect the equipment and components. Common protective measures include:

Cut off the heating power supply: Cut off the power supply of the heating element through relay or contactor to stop heating.

Stop fan operation: Turn off the circulating fan to prevent the hot air from continuing to circulate and avoid further temperature rise.

Issuing alarm signal: Remind the operator of the overheating condition of the equipment through sound and light alarms, and take timely measures.

4. Reset mechanism

When the equipment is overheated and protected, it needs to be restarted only when the temperature drops to a safe range. There are usually two reset methods:

Automatic reset: When the temperature drops to the set safety value, the control system will automatically restore the normal operation of the equipment.

Manual reset: It is necessary for the operator to manually check the status of the equipment and press the reset button after confirming that there is no error before the equipment can be restarted.

Through the above steps, the overheating protection mechanism can effectively prevent the drying oven from causing damage to the electronic components due to the abnormal rise in temperature during operation and ensure the safety of the equipment and operators.